12. Check for continuity between the appropriate vertical acceleration sensor terminals No. 1 and No. 3.
DTC 1-1
DTC 1-2
DTC 1-3
Is there continuity?
YES -
Repair a short in the wires between the appropriate vertical acceleration sensor and the active damper control unit.?
NO -
Go to step 13.
13. Check for continuity between active damper control unit connector B (14P) terminal No. 11 and appropriate vertical acceleration sensor 3P
connector terminal No.2 (see table).