Is there continuity?
YES -
Go to step 13.
NO -
Repair an open in the wire between the appropriate suspension stroke sensor and the active damper control unit.?
13. Check for continuity between active damper control unit connector B (14P) terminal No. 4 and appropriate suspension stroke sensor 3P
connector terminal No. 1 (see table).
Is there continuity?
YES -
Go to step 14.
NO -
Repair an open in the wire between the appropriate suspension stroke sensor and the active damper control unit.?
14. Reconnect active damper control unit connector A (20P) and connector B (14P).
15. Start the engine, and wait 5 seconds.
16. Measure the voltage between body ground and appropriate suspension stroke sensor 3P connector terminal No. 1.