Friday, June 5, 2020

2010 Acura Truck MDX V6-3.7L Page 128


Is there continuity?



YES -



Go to step 13.



NO -



Repair an open in the wire between the appropriate suspension stroke sensor and the active damper control unit.?



13. Check for continuity between active damper control unit connector B (14P) terminal No. 4 and appropriate suspension stroke sensor 3P



connector terminal No. 1 (see table).



Is there continuity?



YES -



Go to step 14.



NO -



Repair an open in the wire between the appropriate suspension stroke sensor and the active damper control unit.?



14. Reconnect active damper control unit connector A (20P) and connector B (14P).



15. Start the engine, and wait 5 seconds.



16. Measure the voltage between body ground and appropriate suspension stroke sensor 3P connector terminal No. 1.