Tuesday, September 1, 2020

2010 Acura Truck MDX V6-3.7L Page 26


Intermittent failure, the system is OK at this time.?



4. Turn the ignition switch to LOCK (0).



5. Disconnect the right BSI alert indicator 2P connector.



6. Measure the resistance between right BSI alert indicator 2P connector terminal No. 1 and body ground. There should be less than 1.0 Ohms.



Is the resistance as specified?



YES -



Go to step 7.



NO -



Repair an open in the wire between the right BSI alert indicator and body ground (G507).?



7. Turn the ignition switch to ON (II), and within 3 seconds measure the voltage between right BSI alert indicator 2P connector terminals No. 1



and No. 2.



Does the voltage remain between 12 V and 1 V for 3 seconds after turning the ignition switch to ON (II), then go down to 0 V?



YES -



Replace the right BSI alert indicator.?



NO -



Go to step 8.



8. Turn the ignition switch to LOCK (0).



9. Disconnect the BSI control unit 16P connector.



10. Measure the resistance between right BSI alert indicator 2P connector terminal No. 2 and body ground. There should be an open circuit or at